Section 24-522 - Front setbacks in districts where front yards are not required
R6 R7 R8 R9 R10 R11 R12
In the districts indicated without a letter suffix,if the front wall or other portion of a building or other structure is located at the street line or within the initial setback distance set forth in the table in this Section, the height of such front wall or other portion of a building or other structure shall not exceed the maximum height above curb level set forth in the table. Above such specified maximum height and beyond the initial setback distance , the building or other structure shall not penetrate the sky exposure plane set forth in the table:
MAXIMUM HEIGHT OF FRONT WALL AND REQUIRED FRONT SETBACKS
Initial Setback Distance (in feet) Maximum Height of a Front Wall or other portion of a Building or other structure within the Initial Setback Distance Sky Exposure Plane Height above Street Line (in feet) Slope over Zoning Lot (expressed as a ratio of vertical distance to horizontal distance) On Narrow Street On Wide Street On Narrow Street On Wide Street Vertical Distance Horizontal Distance Vertical Distance Horizontal Distance R6 or R7 Districts 20 15 60 feet or six stories , whichever is less 60 2.7 to 1 5.6 to 1 R8, R9, R10, R11 or R12 Districts 20 15 85 feet or nine stories , whichever is less 85 2.7 to 1 5.6 to 1
SKY EXPOSURE PLANE R6, R7, R8, R9, R10, R11, R12 Districts