Section 23-353 - Outer court regulations
R1 R2 R3 R4 R5 R6 R7 R8 R9 R10 R11 R12
In the districts indicated, the following outer court regulations shall apply:
where legally required windows face onto an outer court , the width of such outer court shall be at least equal to the depth of such outer court , except that an outer court may extend to any depth where the width of the outer court is 20 feet or more in buildings or portions thereof, at or below a height of 75 feet, or where the width of the outer court is 30 feet or more above a height of 75 feet, where permitted; where no legally required windows face onto an outer court , for buildings or portions thereof at or below a height of 75 feet, the area of such small outer court shall not be less than 200 square feet and no dimension shall be less than 10 feet, and above a height of 75 feet, where permitted, the area of such small outer court shall not be less than 300 square feet and no dimension shall be less than 15 feet; and the width of an outer court recess shall be at least equal to the depth of the outer court recess , except where such width permits any depth for an outer court , relative to the height.